Gas Metering
Clamp-On Ultrasonic Gas Meters: Choosing the Measuring Point
A clamp-on meter has no spool and no flow calibration in the pipe, so its installed accuracy depends on where the transducers go, on signals carried by the pipe wall, and on the signal quality recorded at commissioning.
What a clamp-on meter does not have
An inline ultrasonic gas meter arrives as a spool: its transducers are fixed, its geometry has been measured and, for custody transfer, a flow calibration is on record. ISO 17089-1 is the standard for ultrasonic gas meters. A clamp-on meter has none of that in the pipe. Its transducers are clamped to a pipe whose wall thickness, roundness and inner condition come from data entered on site, and the flow profile at the measuring point is whatever the upstream piping produces.
So the installed accuracy of a clamp-on meter is settled on site, mostly by the choice of measuring point. The examples here come from one manufacturer's manual, FLEXIM's operating instruction for FLUXUS G72x (V2-2).
Straight runs, and which side of the pipe
The manual's table of recommended distances from disturbances (Tab. 3.2, pp.17 to 19) includes these. A 90° elbow upstream needs at least 10 D of straight pipe before the transducers, and one downstream needs 3 d after them. A directly coupled double elbow out of plane needs 40 D, a 45° elbow 15 D, a valve 40 d, a reducer 10 D and a compressor 20 d. With the transmitter's flow disturbance correction, the manual allows 2 d for the elbows and the reducer.
Two letters appear in that table. Its legend defines d as the inner pipe diameter at the measuring point. Capital D is not defined in the table itself; the manual's next section uses D for the outer pipe diameter (p.20). These are one manufacturer's recommendations for its own instrument, not general values for every clamp-on meter.
On a horizontal pipe, the transducers go on the side of the pipe, not the top, so that the sound crosses the pipe horizontally and liquid or solids at the bottom stay out of its path (p.17). On a gas line that mostly means condensate. The same page asks for a measuring point with no liquid accumulation, which rules out low points and the section just upstream of an orifice plate.
Flanges, and signals in the pipe wall
Ultrasound travels in the pipe wall as well as in the gas, and flanges reflect it (p.20); a weld can also be a reflection point (p.38). The manual names two places to avoid. One is within 3 D of the reflection point. The other is a band at (l_S ± 2) D from it, where the reflected wall signal and the measuring signal reach the transducer at the same time.
The manual defines l_S = (n/2) × (c_β/c_γ) × D, where n is the number of sound paths, c_β the sound speed of the pipe, c_γ the sound speed of the fluid and D the outer pipe diameter (p.20). Sound in a steel wall is several times faster than in gas, so on a gas line l_S lands several diameters from the flange, often inside the straight run that the flow profile needs.
Where the distances cannot be kept, pipe damping mats fitted around the pipe reduce the noise carried along the wall. The manual's test for whether they are needed is a measured one: if the SCNR (signal-to-correlated noise ratio) is above 40 dB, they are not (p.38).
Arrangement, and the commissioning baseline
The transducers are mounted either in diagonal arrangement, on opposite sides of the pipe, or in reflection arrangement, on the same side (p.15). The number of sound paths is odd in diagonal arrangement and even in reflection arrangement, and that number is the n in l_S. Changing the arrangement on site therefore moves the band to avoid.
Once the measurement starts, the transmitter displays diagnostic values. The manual rates a measurement as good when SCNR is above 30 dB, SNR (signal-to-noise ratio) is above 15 dB and GAIN (signal gain) is below 98 dB (p.135). Record these on the commissioning sheet, with the transducer distance and the pipe data entered. A later fall in SCNR or rise in gain says something at the measuring point has changed, such as deposits or liquid, which the manual lists among the causes of signal attenuation (p.17). Without the first record there is nothing to compare against.