Gas Metering
Gauge or Absolute, 0 °C or 15 °C: Gas Flow at Standard Conditions
Standard gas volume rests on three converter settings, and each of them, set wrong, gives a stable number that is wrong.
One equation, three settings
A gas meter measures volume at line conditions. The contract settles on volume at reference conditions, so a flow computer, or the meter's own transmitter, converts one into the other. One clamp-on transmitter's manual (FLEXIM FLUXUS G72x) writes the conversion as Q_N = Q × (p/p_N) × (T_N/T) × (1/K), where K = Z/Z_N is the ratio of the gas compressibility factors at operating and at standard conditions (p.12). It is the ideal gas law with a compressibility correction, the same form any converter uses.
The manual states that p and p_N are absolute pressures, and that T and T_N are in kelvin. Three things in that equation are settings someone types in or wires up: the reference conditions, the pressure basis and K. Get one wrong and the result is steady, repeatable and off by a fixed amount. Nothing on the display looks wrong.
Reference conditions: 0 °C is not 15 °C
That transmitter's defaults are p_N = 1.013 bar(a) and T_N = 0 °C, and both can be changed (p.12). Many gas contracts use another basis. The ISO 13443 standard reference conditions are 15 °C and 101.325 kPa, and some contracts use 15.56 °C (60 °F). Whatever the contract says has to be entered explicitly. A default left in place is a contract term that neither party agreed to.
The size of the error follows from T_N/T alone. Moving T_N from 0 °C to 15 °C multiplies standard volume by 288.15/273.15 ≈ 1.055, so the same gas reads about 5.5 % higher on a 15 °C basis than on a 0 °C basis. Seen from the contract side, a converter left at 0 °C on a 15 °C contract reports about 5.2 % less than the correct figure.
A gauge reading in an absolute input
The p in the equation is absolute. Pressure transmitters on a gas skid are often gauge instruments, and the converter has no way of knowing which kind is wired to it. If a gauge reading goes into an absolute input, the converter works with a pressure one atmosphere too low. On a line at about 50 bar(a), standard volume then reads low by about 1.013/50 ≈ 2.0 %, for every hour the meter runs.
The error grows as pressure falls, because the same atmosphere is a larger share of the line pressure: at 10 bar(a) it is close to 10 %. Comparing the transmitter's data sheet with the pressure unit configured in the converter, and the input reading with line pressure plus atmospheric pressure, takes a few minutes at commissioning.
Compressibility, and constants left in
K corrects for real-gas behaviour. Z at line conditions is calculated from gas composition, pressure and temperature by a method such as AGA Report No. 8 or ISO 12213, and Z_N is the same quantity at reference conditions. In the FLUXUS transmitter, K is either stored in the fluid's data set or entered by the user (p.12). An entered K is right only for the composition, pressure and temperature it was worked out for.
The same manual lets operating pressure and temperature come from live inputs or be entered as constant values (p.12). Constants are useful during commissioning, before the transmitters are connected. Left in afterwards, they are an error that no alarm reports: the converter keeps applying the pressure and temperature of the day it was set up while the line moves away from them.
A short check closes most of this off. Write down T_N, p_N, the pressure basis of each input, the source of K and whether p and T are live, then compare them with the contract basis before the first period is settled.