- Measurement technology
- Coriolis mass flow meters (Emerson)
- Stream arrangement
- 3 × 100% — duty, stand-by and master (N+1+1)
- Proving method
- Master-meter stream in Z-configuration
- Design standards
- AGA Report 11, OIML R137-1 and IPS
- Accuracy
- Maximum permissible error ±0.5% on the duty meters and ±0.25% on the master meter
- System uncertainty
- Better than ±0.7%
- Calibration
- At ISO 17025-accredited centres, attended by the client's representative
- Process connection
- 12-inch 300# inlet header with 10-inch meter runs
- Area classification
- Hazardous area
- Control system
- Flow computers, functional logic, control architecture and HMI graphics
- Testing
- FAT, SAT, pressure testing, radiography, PT, full I/O check and performance test
- Certification
- Custody-transfer certification with the regulatory authority, and handover to the client